sane-microtek2(5)  SANE Scanner Access Now Easy sane-microtek2(5)

NAME
       sane-microtek2  -  SANE backend for Microtek scanners with
       SCSI-2 command set

DESCRIPTION
       The sane-microtek2  library  implements	a  SANE	 (Scanner
       Access  Now Easy) backend that provides access to Microtek
       scanners with a SCSI-2 command set.  This backend  can  be
       considered alpha to beta. Some scanner models are reported
       to work well, others not. New development versions of this
       backend	can  be	 obtained  from http://karstenfestag.gmx-
       home.de

       There exists a different	 backend  for  Microtek	 scanners
       with  SCSI-1  command  set.  Refer to sane-microtek(5) for
       details.

       And there is work in progress for the ScanMaker 3600.  See
       http://sourceforge.net/projects/sm3600

       At present, the following scanners are known positively to
       work with this backend:

       Vendor	  Product id:	     Remark
       --------	  --------------     -------------
       Microtek	  E3+		     Parport and SCSI
       Microtek	  X6		     SCSI
       Microtek	  X6EL		     SCSI
       Microtek	  X6USB		     USB
       Microtek	  ScanMaker V300     Parport and SCSI
       Microtek	  ScanMaker V310     Parport and SCSI
       Microtek	  ScanMaker V600     Parport and SCSI
       Microtek	  ScanMaker 330	     SCSI
       Microtek	  ScanMaker 630	     SCSI
       Microtek	  ScanMaker 636	     SCSI
       Microtek	  ScanMaker 9600XL   SCSI; only flatbed mode?
       Microtek	  Phantom 330CX	     Parport
       Microtek	  SlimScan C3	     Parport
       Microtek	  SlimScan C6	     USB
       Microtek	  Phantom 636	     SCSI
       Microtek	  Phantom 636CX	     Parport
       Microtek	  V6USL		     SCSI and USB
       Microtek	  V6UPL		     USB; not stable
       Microtek	  X12USL	     SCSI; only 8bit color,  work
       in progress
       Vobis	  HighScan	     SCSI (E3+ based models)
       Scanport	  SQ300		     Parport?
       Scanport	  SQ4836	     SCSI
       Scanpaq	  SQ2030	     Parport

       Additional     information     can     be     found     at
       http://www.mostang.com/sane/ .

       If you own a Microtek scanner other than the  ones  listed
       above,  it  may	or  may not work with SANE! Because equal
       scanners are sold under different names in different coun-
       tries your model may be equivalent to one of the above.

       The  parport scanners work with the ppscsi + onscsi kernel
       modules. See http://www.torque.net/parport/ppscsi.html

       The USB scanners work with the microtek kernel module. You
       may  have  to add the vendor and model codes to microtek.c
       if they aren't yet listed there.

       Both parport and USB scanners need the generic  SCSI  sup-
       port, so check if you have loaded the scsi_mod and sg mod-
       ules!

       If you try your scanner for the first time keep an eye  on
       it.  If	it  gets  commands that it doesn't understand the
       scanhead may go beyond the scan area.   The  scanner  then
       makes strange noises. In this case immedieately switch off
       the scanner or disconnect its power cable to prevent  dam-
       ages!

       If  your	 scanner  is a different one than the models men-
       tioned above and it is  working	please	tell  the  author
       about  it.  It  would be nice if you add a logfile to this
       information (creation of the logfile: see below).

       If your scanner is not working properly	you  also  should
       create  a  logfile  and send it to the author. He will use
       the information to improve the backend and  possibly  make
       your scanner work.

       How to create the logfile?

       - put the line
	      "option dump 2" into your microtek2.conf
	       file or change the existing "option dump" to "2"

       - in a terminal (bash) type
	      "export SANE_DEBUG_MICROTEK2=30" and then
	      "scanimage -l0 -t0 -x100 -y20 2>scan.log >sout.pnm"
	      You get two files: scan.log  contains  the  logfile
	      and  sout.pnm  the  scanned  image  (if  there  was
	      scanned something). Zip them before sending.

FRONTEND OPTIONS
       This backend dynamically enables the options for the fron-
       tend,  that  are supported by the scanner in dependence of
       the  scanning-mode  and	other  options.	  Not	supported
       options are disabled.

       The    following	   options    are    supported	 by   the
       Microtek2-driver:

       Color, grayscale, halftone and lineart scans.

       Highlight, midtone, shadow, contrast, brightness, exposure
       time  control,  gamma  correction, threshold (dependent of
       the scan mode and the scanner capabilities)

       Transparency media adapter, automatic document feeder

       Additional options can  be  enabled  or	disabled  in  the
       microtek2.conf file. See the configuration section of this
       manpage.

DEVICE NAMES
       This backend expects device names of the form:

	      special

       Where special is the UNIX path-name for the special device
       that  corresponds to the scanner.  The special device name
       must be a generic SCSI device  or  a  symlink  to  such	a
       device.	Under Linux, such a device name could be /dev/sga
       or /dev/sge for example.

CONFIGURATION
       The  configuration  file	 for  this  backend  resides   in
       /usr/freeware/etc/sane.d/microtek2.conf	Its contents is a
       list of device names that correspond to Microtek	 scanners
       with SCSI-2 interface. Empty lines and lines starting with
       a hash mark (#) are ignored.

       The configuration file may also	contain	 options.  Global
       options	that  are  valid for all devices are placed above
       the device names. Device-specific options are placed under
       the device name. Note that, except for option dump <n> and
       option strip-height <n>, the entry in  the  microtek2.conf
       file  only  enables  the	 corresponding	option	for being
       showed in the frontend. There, in the  frontend,	 you  can
       switch  the  options  on and off.  Currently the following
       options are supported:

	      option dump <n>
	      option strip-height <n>
	      option no-backtrack-option <on/off>
	      option lightlid-35 <on/off>
	      option toggle-lamp <on/off>
	      option lineart-autoadjust <on/off>
	      option backend-calibration <on/off>
	      option colorbalance-adjust <on/off>

       option dump <n> enables printing of additional information
       about  the  SCSI	 commands that are sent to the scanner to
       stderr. This option is primarily useful for debugging pur-
       pose.  This  option  has to be a global option and is best
       placed at the top of the microtek2.conf file.

       If n=1 the contents of the command blocks and the  results
       for  the	 INQUIRY  and READ SCANNER ATTRIBUTES command are
       printed to stderr.

       If n=2 the contents of the command blocks  for  all  other
       SCSI  commands are printed to stderr, too. If n=3 the con-
       tents of the gamma table is printed, too. If n=4 all  scan
       data is additionally printed to stderr.

       The default is n=1.

       option  strip-height  <n>  , where <n> is a floating point
       number, limits the amount of data that is  read	from  the
       scanner	with  one read command.	 The unit is inch and <n>
       defaults to 1.0, if this option is not set in the configu-
       ration  file.  If  less than <n> inch of data fit into the
       SCSI buffer, then the  smaller  value  is  used	and  this
       option has no effect.

       If  your system has a big SCSI buffer and you want to make
       use of the whole buffer, increase the value for	<n>.  For
       example,	 if <n> is set to 14.0, no restrictions apply for
       scanners with a letter, legal or A4 sized scan area.

       The following options enable or disable	additional  fron-
       tend  options.  If an option is set to <on> an appropriate
       option will appear in the frontend.

       option no-backtrack-option <on/off> prevents  the  scanner
       head  from  moving  backwards  between  the read commands.
       This speeds up scanning. Try it.

       option lightlid-35 <on/off> If  you  use	 the  LightLid-35
       transparency  adapter  you  get	an  advanced option which
       switches off the flatbed lamp during the scan.

       option toggle-lamp <on/off> You get a button in the  fron-
       tend where you can switch on and off the flatbed lamp.

       option  lineart-autoadjust <on/off> You can tell the back-
       end to try to determine	a  good	 value	for  the  lineart
       threshold.

       option  backend-calibration  <on/off>  Some scanners (e.g.
       Phantom 330CX and 636CX) need to have calibrated the  data
       by  the	backend.  Try  this  option  if	 you see vertical
       stripes in your pictures.

       option colorbalance-adjust <on/off>  Some  scanners  (e.g.
       Phantom	330CX and 636CX) need to have corrected the color
       balance. If  this  option  is  enabled  you  get	 advanced
       options	where  you  can	 balance the colors. And you will
       have a button to use the values that the firmware  of  the
       scanner provides.

       A sample configuration file is shown below:

	      option dump 1
	      option strip-height 1.0
	      /dev/scanner
	      option no-backtrack-option on
	      # this is a comment
	      /dev/sge
	      option lightlid-35 on

       This backend also supports the new configuration file for-
       mat which makes it easier to detect scanners under  Linux.
       If  you	have only one scanner it would be best to use the
       following configuration file for this backend:

	      option dump 1
	      option strip-height 14.0
	      option no-backtrack-option on
	      option backend-calibration on
	      option lightlid-35 on
	      option toggle-lamp on
	      option lineart-autoadjust on
	      option colorbalance-adjust off
	      scsi * * Scanner

       In this case all SCSI-Scanners should be detected automat-
       ically because of the

       scsi * * Scanner

       line.

FILES
       /usr/freeware/etc/sane.d/microtek2.conf
	      The backend configuration file.

       /usr/freeware/lib32/sane/libsane-microtek2.a
	      The static library implementing this backend.

       /usr/freeware/lib32/sane/libsane-microtek2.so
	      The  shared library implementing this backend (pre-
	      sent on systems that support dynamic loading).

ENVIRONMENT
       SANE_DEBUG_MICROTEK2
	      If the library  was  compiled  with  debug  support
	      enabled,	this  environment  variable  controls the
	      debug level for this backend.  E.g., a value of 255
	      requests	all  debug output to be printed.  Smaller
	      levels reduce verbosity. To see error  messages  on
	      stderr  set  SANE_DEBUG_MICROTEK2 to 1 (Remark: The
	      whole debugging levels should be better revised).
	      E.g. just say:
	      export SANE_DEBUG_MICROTEK2=128

SEE ALSO
       sane-scsi(5), sane(7)

AUTHORS
       Bernd Schroeder (not active anymore)
       Karsten Festag  karsten.festag@gmx.de

sane-backends 1.0.12	   28 Jan 2002		sane-microtek2(5)
[top]

List of man pages available for IRIX

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net