ipmiseld.conf(5)		 ipmiseld.conf		      ipmiseld.conf(5)

NAME
       ipmiseld.conf - ipmiseld configuration file

DESCRIPTION
       The ipmiseld configuration file configures the ipmiseld daemon.

       The default configuration file loaded is /etc//ipmiseld.conf.

       The  configuration  options  that can be specified in the configuration
       file are listed below. Each configuration option must be	 listed	 on  a
       separate	 line.	Arguments for an option are separated by any amount of
       whitespace. Multiple arguments are also separated by whitespace.	  Com‐
       ments  can be marked by using the pound sign ("#") character, and lines
       can be continued on the next using backslash ("\").

       Note that it is possible to  list  the  username,  password  and	 other
       potentially  sensitive  information  in the configuration file. If this
       data is stored in a configuration file,	system	administrators	should
       limit access to this file.

IPMISELD CONFIGURATION OPTIONS
       driver-type IPMIDRIVER
	      Specify the driver type to use.

       disable-auto-probe ENABLE|DISABLE
	      Specify if IPMI devices should be probed for settings.

       driver-address DRIVER-ADDRESS
	      Specify the in-band driver address to use.

       driver-device DEVICE
	      Specify the in-band driver device path to use.

       register-spacing REGISTER-SPACING
	      Specify the in-band driver register spacing to use.

       target-channel-number CHANNEL-NUMBER
	      Specify the in-band driver target channel number.

       target-slave-address SLAVE-ADDRESS
	      Specify the in-band driver target slave address.

       hostname IPMIHOST1,IPMIHOST2,...
	      Specify  the  remote host(s) to communicate with. Multiple host‐
	      names may be separated by comma or may be specified in  a	 range
	      format.

       username USERNAME
	      Specify the username to use.

       password PASSWORD
	      Specify the password to use.

       k_g str
	      Specify  the BMC key (K_g) to use. Prefix with '0x' to enter the
	      key in hex.

       session-timeout MILLISECONDS
	      Specify the session timeout length to use in milliseconds.

       retransmission-timeout MILLISECONDS
	      Specify the retransmission timeout length to  use	 in  millisec‐
	      onds.

       authentication-type AUTHENTICATION-TYPE
	      Specify  the authentication type to use. The following authenti‐
	      cation types are supported:  NONE,  STRAIGHT_PASSWORD_KEY,  MD2,
	      and MD5.

       cipher-suite-id CIPHER-SUITE-ID
	      Specify  the  cipher suite id to use. The following cipher suite
	      ids are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.

       privilege-level PRIVILEGE-LEVEL
	      Specify the privilege type to use. The following privilege  lev‐
	      els are supported: USER, OPERATOR, ADMIN.

       workaround-flags WORKAROUNDS
	      Specify  workaround  flags  to  use. Multiple workarounds can be
	      specified separated by whitespace. Please see tool manpages  for
	      details about available workarounds for each tool. The following
	      workarounds are  supported:  assumeio,  spinpoll,	 idzero,  for‐
	      cepermsg,	 unexpectedauth, endianseq, authcap, intel20, supermi‐
	      cro20, sun20,  opensesspriv,  integritycheckvalue,  assumesyste‐
	      mevent.

       verbose-count COUNT
	      Specify default verbose count to use for ipmi-sel(8).

       sensors-types TYPE-LIST
	      Specify sensor types of SEL events to log. Multiple types can be
	      specified separated by  whitespace.  Users  may  specify	sensor
	      types  by string or by number (decimal or hex). Please see ipmi-
	      sel(8) --list-types option to see possible string input types.

       exclude-sensor-types ENSOR-TYPES-LIST
	      Specify sensor types of SEL events to not	 log.  default	sensor
	      types  to not show sensor outputs for. Multiple sensor types can
	      be specified separated by whitespace. Users may  specify	sensor
	      types   by   string   or	 by  number.  Please  see  ipmi-sel(8)
	      --list-types option to see possible string input types.

       system-event-only ENABLE|DISABLE
	      Specify if output should only include system event records.

       oem-event-only ENABLE|DISABLE
	      Specify if output should only include OEM event records.

       event-state-config-file FILE
	      Specify the event state configuration file.

       interpret-oem-data ENABLE|DISABLE
	      Specify if ipmiseld should attempt to interpret OEM data or not.

       entity-sensor-names ENABLE|DISABLE
	      Specify if output of sensor names should include entity ids  and
	      instances or not.

       non-abbreviated-units ENABLE|DISABLE
	      Specify  if  output  should have units abbreviated by default or
	      not.

       event-state-filter FILTERSTRING
	      Specify event states to be filtered out and not logged.

       --warning-threshold PERCENTINT
	      Specify SEL fullness warning threshold as an integer percentage.

       --clear-threshold PERCENTINT
	      Specify SEL fullness clear threshold as an integer percentage.

       system-event-format FORMATSTRING
	      Specify the format of the log output when a SEL system event  is
	      encountered.

       oem-timestamped-event-format FORMATSTRING
	      Specify  the format of the log output when a SEL OEM timestamped
	      event is encountered.

       oem-non-timestamped-event-format FORMATSTRING
	      Specify the format of the log output when a SEL  OEM  non-times‐
	      tamped event is encountered.

       poll-interval SECONDS
	      Specify the poll interval to check the SEL for new events.

       log-facility STRING
	      Specify the log facility to use.

       log-priority STRING
	      Specify the log priority to use.

       cache-directory DIRECTORY
	      Specify the cache directory to use.

       ignore-sdr DISABLE
	      Specify if the SDR should be ignored.

       re-download-sdr DISABLE
	      Specify if the SDR should be re-downloaded on start.

       clear-sel DISABLE
	      Specify if the SEL should be cleared on start.

       threadpool-count NUM
	      Specify the threadpool count for parallel SEL polling.

FILES
       /etc//ipmiseld.conf

REPORTING BUGS
       Report bugs to <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

COPYRIGHT
       Copyright (C) 2012 Lawrence Livermore National Security, LLC.

SEE ALSO
       ipmiseld(8), ipmi-sel(8)

       http://www.gnu.org/software/freeipmi/

ipmiseld.conf 1.2.1		  2013-11-21		      ipmiseld.conf(5)
[top]

List of man pages available for Scientific

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net