termiox(7I)			Ioctl Requests			   termiox(7I)

NAME
       termiox - extended general terminal interface

DESCRIPTION
       The extended general terminal interface supplements the termio(7I) gen‐
       eral terminal interface by adding  support  for	asynchronous  hardware
       flow  control,  isochronous  flow  control  and	clock modes, and local
       implementations of additional asynchronous features. Some  systems  may
       not  support  all  of  these capabilities because of either hardware or
       software limitations.  Other systems may not permit  certain  functions
       to  be  disabled.  In these cases the appropriate bits will be ignored.
       See <sys/termiox.h> for your system to find out which capabilities  are
       supported.

   Hardware Flow Control Modes
       Hardware flow control supplements the termio(7I) IXON, IXOFF, and IXANY
       character flow control. Character flow control occurs when  one	device
       controls	 the  data transfer of another device by the insertion of con‐
       trol characters in the data stream between devices.  Hardware flow con‐
       trol  occurs  when  one	device	controls  the data transfer of another
       device using electrical control signals	on  wires  (circuits)  of  the
       asynchronous  interface.	 Isochronous hardware flow control occurs when
       one device controls the data transfer of another device	by   asserting
       or  removing the transmit clock signals of that device.	Character flow
       control and hardware flow control may be simultaneously set.

       In asynchronous, full duplex applications, the use  of  the  Electronic
       Industries  Association's  EIA-232-D Request To Send (RTS) and Clear To
       Send (CTS) circuits is the  preferred method of hardware flow  control.
       An interface to other hardware flow control methods is included to pro‐
       vide a standard interface to these existing methods.

       The EIA-232-D standard specified only unidirectional hardware flow con‐
       trol  -	the  Data Circuit-terminating Equipment or Data Communications
       Equipment (DCE) indicates to the Data Terminal Equipment (DTE) to  stop
       transmitting  data.    The termiox interface allows both unidirectional
       and bidirectional hardware flow control; when bidirectional  flow  con‐
       trol  is	 enabled,  either the DCE or DTE can indicate to each other to
       stop transmitting data across the interface.  Note: It is assumed  that
       the  asynchronous port is configured as a DTE.  If the connected device
       is also a DTE and not a DCE, then DTE to DTE (for example, terminal  or
       printer	connected  to  computer)  hardware flow control is possible by
       using a null modem to interconnect the  appropriate  data  and  control
       circuits.

   Clock Modes
       Isochronous  communication is a variation of asynchronous communication
       whereby two communicating devices may provide transmit  and/or  receive
       clock  signals to one another. Incoming clock signals can be taken from
       the baud rate generator on the local isochronous port controller,  from
       CCITT  V.24 circuit 114, Transmitter Signal Element Timing - DCE source
       (EIA-232-D pin 15), or  from CCITT V.24 circuit	115,  Receiver	Signal
       Element Timing - DCE source  (EIA-232-D pin 17). Outgoing clock signals
       can be sent on CCITT V.24 circuit 113, Transmitter Signal Element  Tim‐
       ing  -  DTE  source  (EIA-232-D	 pin  24),  on CCITT V.24 circuit 128,
       Receiver Signal Element Timing - DTE source (no EIA-232-D pin), or  not
       sent at all.

       In  terms  of  clock  modes,  traditional asynchronous communication is
       implemented simply by using the local baud rate generator as the incom‐
       ing transmit and receive clock source and not outputting any clock sig‐
       nals.

   Terminal Parameters
       The parameters that control  the	 behavior  of  devices	providing  the
       termiox interface are specified by the termiox structure defined in the
       <sys/termiox.h> header.	Several ioctl(2) system calls  that  fetch  or
       change these parameters use this structure:

       #define	 NFF  5
       struct termiox {
	    unsigned short x_hflag;	  /* hardware flow control modes */
	    unsigned short x_cflag;	  /* clock modes */
	    unsigned short x_rflag[NFF];  /* reserved modes */
	    unsigned short x_sflag;	  /* spare local modes */
       };

       The x_hflag field describes hardware flow control modes:

       RTSXOFF	       0000001	    Enable RTS hardware flow control
				    on input.
       CTSXON	       0000002	    Enable CTS hardware flow control
				    on output.
       DTRXOFF	       0000004	    Enable DTR hardware flow control
				    on input.
       CDXON	       0000010	    Enable CD hardware flow  control
				    on output.
       ISXOFF	       0000020	    Enable isochronous hardware flow
				    control on input

       The EIA-232-D DTR and CD circuits are used to  establish	 a  connection
       between	two  systems. The RTS circuit is also used to establish a con‐
       nection with a modem. Thus, both DTR and	 RTS  are  activated  when  an
       asynchronous  port is opened. If DTR is used for hardware flow control,
       then RTS must be used for connectivity. If CD is used for hardware flow
       control,	 then CTS must be used for connectivity. Thus, RTS and DTR (or
       CTS and CD) cannot both be used for hardware flow control at  the  same
       time.  Other mutual exclusions may apply, such as the simultaneous set‐
       ting of the termio(7I) HUPCL and the  termiox DTRXOFF bits,  which  use
       the DTE ready line for different functions.

       Variations  of  different hardware flow control methods may be selected
       by setting the the appropriate bits. For example, bidirectional RTS/CTS
       flow  control  is  selected by setting both the RTSXOFF and CTSXON bits
       and bidirectional DTR/CTS flow control is selected by setting both  the
       DTRXOFF	and  CTSXON. Modem control or unidirectional CTS hardware flow
       control is selected by setting only the CTSXON bit.

       As previously mentioned, it is assumed that the local asynchronous port
       (for  example,  computer)  is  configured  as  a DTE.  If the connected
       device (for example,  printer) is also a DTE, it is  assumed  that  the
       device  is  connected  to the computer's asynchronous port using a null
       modem that swaps control circuits (typically RTS and  CTS).   The  con‐
       nected DTE drives RTS and the null modem swaps RTS  and CTS so that the
       remote RTS is received as CTS by the  local  DTE.   In  the  case  that
       CTSXON  is set for hardware flow control, printer's lowering of its RTS
       would cause CTS seen by the computer to	be  lowered.   Output  to  the
       printer	is  suspended  until  the  printer's raising of its RTS, which
       would cause CTS seen by the computer to be raised.

       If RTSXOFF is set, the Request To Send (RTS)  circuit  (line)  will  be
       raised,	and  if the asynchronous port needs to have its input stopped,
       it will lower the Request To Send (RTS) line. If the RTS line  is  low‐
       ered,  it  is  assumed  that  the connected device will stop its output
       until RTS is raised.

       If CTSXON is set, output will occur only if the	Clear  To  Send	 (CTS)
       circuit	(line)	is  raised by the connected device. If the CTS line is
       lowered by the connected device,	 output	 is  suspended	until  CTS  is
       raised.

       If  DTRXOFF  is set, the DTE Ready (DTR) circuit (line) will be raised,
       and if the asynchronous port needs to have its input stopped,  it  will
       lower  the  DTE	Ready  (DTR)  line.  If the DTR line is lowered, it is
       assumed that the connected device will stop its	output	until  DTR  is
       raised.

       If  CDXON  is  set,  output will occur only if the Received Line Signal
       Detector (CD) circuit (line) is raised by the connected device. If  the
       CD  line	 is lowered by the connected device, output is suspended until
       CD is raised.

       If ISXOFF is set, and if the isochronous port needs to have  its	 input
       stopped, it will stop the outgoing clock signal. It is assumed that the
       connected device is using this clock signal to create its output. Tran‐
       sit  and receive clock sources are programmed using the x_cflag fields.
       If the port is not programmed for external clock generation, ISXOFF  is
       ignored.	  Output  isochronous flow control is supported by appropriate
       clock source programming using the x_cflag field	 and  enabled  at  the
       remote connected device.

       The x_cflag field specifies the system treatment of clock modes.

       XMTCLK		 0000007     Transmit clock source:
       XCIBRG		 0000000     Get  transmit clock from inter‐
				     nal baud rate generator.
       XCTSET		 0000001     Get transmit clock from  trans‐
				     mitter  signal  element  timing
				     (DCE source) lead,	 CCITT	V.24
				     circuit 114, EIA-232-D pin 15.
       XCRSET		 0000002     Get    transmit	clock	from
				     receiver signal element  timing
				     (DCE  source)  lead, CCITT V.24
				     circuit 115, EIA-232-D pin 17.
       RCVCLK		 0000070     Receive clock source:
       RCIBRG		 0000000     Get receive clock from internal
				     baud rate generator.
       RCTSET		 0000010     Get  receive  clock from trans‐
				     mitter  signal  element  timing
				     (DCE  source)  lead, CCITT V.24
				     circuit 114, EIA-232-D pin 15.
       RCRSET		 0000020     Get receive clock from receiver
				     signal   element	timing	(DCE
				     source) lead, CCITT  V.24	cir‐
				     cuit 115, EIA-232-D pin 17.
       TSETCLK		 0000700     Transmitter signal element tim‐
				     ing (DTE  source)	lead,  CCITT
				     V.24 circuit 113, EIA-232-D pin
				     24, clock source:
       TSETCOFF		 0000000     TSET clock not provided.
       TSETCRBRG	 0000100     Output receive baud rate gener‐
				     ator on circuit 113.
       TSETCTBRG	 0000200     Output  transmit baud rate gen‐
				     erator on circuit 113
       TSETCTSET	 0000300     Output transmitter signal	ele‐
				     ment  timing  (DCE	 source)  on
				     circuit 113.

       TSETCRSET	 0000400     Output receiver signal  element
				     timing  (DCE source) on circuit
				     113.
       RSETCLK		 0007000     Receiver signal element  timing
				     (DTE  source)  lead, CCITT V.24
				     circuit 128, no EIA-232-D	pin,
				     clock source:
       RSETCOFF		 0000000     RSET clock not provided.
       RSETCRBRG	 0001000     Output receive baud rate gener‐
				     ator on circuit 128.
       RSETCTBRG	 0002000     Output transmit baud rate	gen‐
				     erator on circuit 128.
       RSETCTSET	 0003000     Output  transmitter signal ele‐
				     ment  timing  (DCE	 source)  on
				     circuit 128.
       RSETCRSET	 0004000     Output  receiver signal element
				     timing (DCE) on circuit 128.

       If the XMTCLK field has a value of XCIBRG the transmit clock  is	 taken
       from  the hardware internal baud rate generator, as in normal asynchro‐
       nous transmission.  If XMTCLK = XCTSET the transmit clock is taken from
       the Transmitter Signal Element Timing (DCE source) circuit. If XMTCLK =
       XCRSET the transmit clock is taken from	the  Receiver  Signal  Element
       Timing (DCE source) circuit.

       If  the	RCVCLK	field has a value of RCIBRG the receive clock is taken
       from the hardware Internal Baud Rate Generator, as in normal  asynchro‐
       nous  transmission.  If RCVCLK = RCTSET the receive clock is taken from
       the Transmitter Signal Element Timing (DCE source) circuit. If RCVCLK =
       RCRSET the receive clock is taken from the Receiver Signal Element Tim‐
       ing (DCE source) circuit.

       If the TSETCLK field has a value of  TSETCOFF  the  Transmitter	Signal
       Element Timing (DTE source) circuit is not driven. If TSETCLK = TSETCR‐
       BRG the Transmitter Signal  Element  Timing  (DTE  source)  circuit  is
       driven  by  the Receive Baud Rate Generator. If TSETCLK = TSETCTBRG the
       Transmitter Signal Element Timing (DTE source) circuit is driven by the
       Transmit	 Baud  Rate  Generator. If TSETCLK = TSETCTSET the Transmitter
       Signal Element Timing (DTE source) circuit is driven by the Transmitter
       Signal  Element	Timing (DCE source). If TSETCLK = TSETCRBRG the Trans‐
       mitter Signal Element Timing (DTE source)  circuit  is  driven  by  the
       Receiver Signal Element Timing (DCE source).

       If  the	RSETCLK field has a value of RSETCOFF the Receiver Signal Ele‐
       ment Timing (DTE source) circuit is not driven. If RSETCLK =  RSETCRBRG
       the  Receiver  Signal  Element Timing (DTE source) circuit is driven by
       the Receive Baud Rate Generator.	 If RSETCLK = RSETCTBRG	 the  Receiver
       Signal  Element	Timing	(DTE source) circuit is driven by the Transmit
       Baud Rate Generator. If RSETCLK = RSETCTSET the Receiver Signal Element
       Timing (DTE source) circuit is driven by the Transmitter Signal Element
       Timing (DCE source). If RSETCLK = RSETCRBRG the Receiver Signal Element
       Timing  (DTE  source)  circuit is driven by the Receiver Signal Element
       Timing (DCE source).

       The x_rflag is reserved for future interface definitions and should not
       be used by any implementations. The x_sflag may be used by local imple‐
       mentations wishing to customize	their  terminal	 interface  using  the
       termiox ioctl system calls.

IOCTLS
       The  ioctl(2) system calls have the form:

       ioctl (fildes, command, arg) struct termiox * arg;

       The commands using this form are:

       TCGETX	       The  argument  is a pointer to a termiox structure. The
		       current terminal parameters are fetched and stored into
		       that structure.

       TCSETX	       The  argument is a pointer to a termiox structure.  The
		       current terminal parameters are	set  from  the	values
		       stored in that structure.  The change is immediate.

       TCSETXW	       The  argument is a pointer to a termiox structure.  The
		       current terminal parameters are	set  from  the	values
		       stored  in that structure.  The change occurs after all
		       characters queued for  output  have  been  transmitted.
		       This  form should be used when changing parameters that
		       will affect output.

       TCSETXF	       The argument is a pointer to a termiox structure.   The
		       current	terminal  parameters  are  set from the values
		       stored in that structure.  The change occurs after  all
		       characters queued for output have been transmitted; all
		       characters queued for input are discarded and then  the
		       change occurs.

FILES
       /dev/*

SEE ALSO
       stty(1), ioctl(2), termio(7I)

NOTES
       The   termiox(7I) system call is provided for compatibility with previ‐
       ous releases and	 its use is  discouraged.   Instead,  the   termio(7I)
       system call is recommended.  See termio(7I) for usage information.

SunOS 5.10			  3 Jul 1990			   termiox(7I)
[top]

List of man pages available for SunOS

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net