flashpbay(1M)							 flashpbay(1M)

Name
     flashpbay - FLASH update utility for SGI Server Power Bays

SYNOPSIS
     /usr/sbin/flashpbay [-f] [--l2 hostname|IP]
     [--sysname name] [--ssn serial_number] [--interface name]
     [--serial host:port] [--dev device_name]  image_name
     rack.slot|all|local

     /usr/sbin/flashpbay -version|-v image_name

     Additional IRIX command formats:

     /usr/sbin/flashpbay [-f] [--sc] [--scdev device_name]  image_name
     rack.slot|all|local

DESCRIPTION
     The flashpbay utility updates FLASH memory in the power bay.  The power
     bay flash memory contains the code for communicating status information
     to the L1 controller; it does not control the functional operation of the
     power bay.

     The power bay has two separate flash memories, only one of which is
     accessible for updating by the flashpbay utility. The power bay firmware
     that supports flashing resides in the inaccessible flash memory, so it is
     not possible to corrupt this memory during the flashing procedure. The
     accessible memory, however, may be corrupted if the flashing procedure
     fails for some reason.  In this case, flashpbay will need to be rerun.

     flashpbay supports updates via three methods:
     - ethernet connection to an L2 controller
     - direct USB connection to a L1 controller
     - direct serial connection to an L1 controller

     Valid command line options are:

     -version|-v image_image
	  Return the version number and build time of the specified image.

     -f	  Forces the power bay flash update even if the power bay already is
	  running the same firmware version as the image file.

     --l2 hostname|IP
	  Connect to the L2 controller with the specified hostname or IP
	  address.

									Page 1

flashpbay(1M)							 flashpbay(1M)

     --ssn serial_number
	  Search for an L2 with the System Serial Number serial_number, and
	  connect to the first one found.

     --sysname name
	  Search for an L2 with the System Name name, and connect to the first
	  one found.

     --interface name
	  When searching for an L2 Controller to connect to, only search on
	  the specified network interface (i.e. eth0, eth1, etc.)  This option
	  is ignored when --l2, --serial, or --dev is specified.

     --serial host:port
	  Connect to the controller via a serial (SMP) connection to the Annex
	  box host on network port port (port number of the connection to the
	  Annex box plus 7000).

     --dev device_name
	  Connect to the controller via a direct serial (SMP) connection to a
	  serial port on the system where flashpbay is running.

     --sc (IRIX only) Connect via the system's own System Controller network.
	  This option allows the power bay flash memory firmware to be updated
	  from IRIX.  This option selects causes flashpbay to connect to the
	  L1 Controller of the brick with the lowest numbered rack/slot in the
	  system.  The connection is established by opening one of the
	  /hw/module/*c*/L1/controller devices.

     --scdev device_name
	  (IRIX only) Connect via the system's own System Controller network
	  using device_name.  This option is identical to --sc, except that it
	  uses device_name rather than selecting a default device to use.
	  Valid devices are any of /hw/module/*c*/L1/controller.

     image_name
	  The image name is the file name of the image, which for the power
	  bay is usually pbay.bin.

     rack.slot|all|local
	  rack is the rack number of the controller(s) that will be updated.
	  slot is the slot number of the controller(s) that will be updated.
	  all may be used instead of rack.slot.	 local means update ONLY the
	  controller that flashpbay is connected to (i.e. the L1 it is

									Page 2

flashpbay(1M)							 flashpbay(1M)

	  connected to via a serial connection).  NOTE: The all argument is
	  only valid on systems with one or more L2 Controllers	 (on systems
	  without an L2 Controller, L1 Controllers must be updated
	  individually using the rack.slot or the local argument).

     Without any options, flashpbay attempts to connect to an L2 controller (a
     "real" L2, or a software L2 running on the L3).  When communicating with
     the system via the USB connection (in a system where there is no actual
     L2), the application /stand/sysco/bin/l2 must be running.

FILES
     /usr/sbin/flashpbay  power bay firmware update utility
     /usr/cpu/firmware/sysco/pbay.bin	power bay firmware image
     /hw/module/*c*/L1/controller   (IRIX only) IRIX System Controller devices

EXAMPLES
     Updating all power bays connected to all L1's on a single, standalone
     system with one or more hardware L2's:

     1) cd /usr/cpu/firmware/sysco
     2) /usr/sbin/flashpbay ./pbay.bin all

     Updating all power bays connected to all L1's on one system (serial
     number L0000010) from an L3 Controller with multiple SN1 systems
     connected.

     1) cd /usr/cpu/firmware/sysco
     2) /usr/sbin/flashpbay --ssn L0000010 ./pbay.bin all

     Updating all power bays from IRIX, using the default system controller
     path.  (Note that this command format is valid only on a system with one
     or more L2 Controllers; see the following example for updating systems
     without an L2 controller)

     1) cd /usr/cpu/firmware/sysco
     2) /usr/sbin/flashpbay --sc ./pbay.bin all

     Updating all L1's from IRIX, on a system without an L2 Controller, using
     the default system controller path.  Typically on this type of system,
     all bricks in are connected to the same PowerBay, so the command only
     needs to be executed once (from any of the attached bricks).  In this
     example system there are 3 bricks:	 001c10, 001c13, and 001i16.

     1) cd /usr/cpu/firmware/sysco
     2) /usr/sbin/flashsc --sc ./l1.bin 1.10

									Page 3

flashpbay(1M)							 flashpbay(1M)

     Updating the power bay connected to the L1 at rack 2, slot 18 via the USB
     connection using the L2 emulator running on the L3 (system w/o a hardware
     L2):

     1) make sure the software L2 is running (/stand/sysco/bin/l2)
     2) cd /usr/cpu/firmware/sysco
     3) update the power bay flash with the command:
	/usr/sbin/flashpbay ./pbay.bin 2.18

     Updating the power bay connect to the L1 at rack 3, slot 12 via the
     (serial) SMP port connection on the Annex serial port server 'myannex',
     port 17:

     1) cd /usr/cpu/firmware/sysco
     2) update the power bay flash with the command:
	  /usr/sbin/flashpbay --serial myannex:7017 ./pbay.bin 3.12

									Page 4

[top]

List of man pages available for IRIX

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net