FORT77(P)		   POSIX Programmer's Manual		     FORT77(P)

NAME
       fort77 - FORTRAN compiler (FORTRAN)

SYNOPSIS
       fort77 [-c][-g][-L directory]... [-O optlevel][-o outfile][-s][-w]
	       operand...

DESCRIPTION
       The  fort77 utility is the interface to the FORTRAN compilation system;
       it  shall  accept  the  full  FORTRAN-77	 language   defined   by   the
       ANSI X3.9-1978 standard. The system conceptually consists of a compiler
       and link editor. The files referenced  by  operands  are	 compiled  and
       linked  to  produce  an	executable file. It is unspecified whether the
       linking occurs entirely within the operation of fort77; some  implemen‐
       tations	may produce objects that are not fully resolved until the file
       is executed.

       If the -c option is present, for all pathname operands of the form file
       .f, the files:

	      $(basename pathname.f).o

       shall  be  created  or overwritten as the result of successful compila‐
       tion.  If the -c option is not specified,  it  is  unspecified  whether
       such .o files are created or deleted for the file .f operands.

       If  there are no options that prevent link editing (such as -c) and all
       operands compile and link without error, the resulting executable  file
       shall  be  written into the file named by the -o option (if present) or
       to the file a.out.  The executable file shall be created	 as  specified
       in  the	System	Interfaces volume of IEEE Std 1003.1-2001, except that
       the file permissions shall be set to:

	      S_IRWXO | S_IRWXG | S_IRWXU

       and that the bits specified by  the  umask  of  the  process  shall  be
       cleared.

OPTIONS
       The  fort77  utility  shall  conform  to the Base Definitions volume of
       IEEE Std 1003.1-2001, Section 12.2, Utility Syntax  Guidelines,	except
       that:

	* The  -l library operands have the format of options, but their posi‐
	  tion within a list of operands affects the order in which  libraries
	  are searched.

	* The order of specifying the multiple -L options is significant.

	* Conforming  applications  shall specify each option separately; that
	  is, grouping option letters (for example, -cg) need  not  be	recog‐
	  nized by all implementations.

       The following options shall be supported:

       -c     Suppress	the  link-edit	phase  of  the compilation, and do not
	      remove any object files that are produced.

       -g     Produce symbolic information in the object or executable	files;
	      the  nature of this information is unspecified, and may be modi‐
	      fied by implementation-defined interactions with other options.

       -s     Produce object or executable files, or both, from which symbolic
	      and  other  information  not required for proper execution using
	      the exec family of functions defined in  the  System  Interfaces
	      volume  of  IEEE Std 1003.1-2001 has been removed (stripped). If
	      both -g and -s options are present, the action taken is unspeci‐
	      fied.

       -o  outfile
	      Use  the pathname outfile, instead of the default a.out, for the
	      executable file produced. If the -o option is present  with  -c,
	      the result is unspecified.

       -L  directory
	      Change  the algorithm of searching for the libraries named in -l
	      operands to look in the directory named by the  directory	 path‐
	      name before looking in the usual places. Directories named in -L
	      options shall be searched in the specified order. At  least  ten
	      instances	 of  this option shall be supported in a single fort77
	      command invocation. If a directory specified by a -L option con‐
	      tains a file named libf.a, the results are unspecified.

       -O  optlevel
	      Specify  the level of code optimization. If the optlevel option-
	      argument is the digit '0' , all special code optimizations shall
	      be  disabled.  If	 it is the digit '1' , the nature of the opti‐
	      mization is unspecified. If the -O option is omitted, the nature
	      of  the  system's	 default  optimization	is  unspecified. It is
	      unspecified whether code generated in the presence of the	 -O  0
	      option  is  the same as that generated when -O is omitted. Other
	      optlevel values may be supported.

       -w     Suppress warnings.

       Multiple instances of -L options can be specified.

OPERANDS
       An operand is either in the form of a pathname or the form -l  library.
       At  least one operand of the pathname form shall be specified. The fol‐
       lowing operands shall be supported:

       file.f The pathname of a FORTRAN source file to be compiled and option‐
	      ally passed to the link editor. The filename operand shall be of
	      this form if the -c option is used.

       file.a A library of object files typically produced by ar,  and	passed
	      directly	to  the	 link  editor.	Implementations	 may recognize
	      implementation-defined suffixes other than .a as denoting object
	      file libraries.

       file.o An  object file produced by fort77 -c and passed directly to the
	      link  editor.  Implementations  may  recognize   implementation-
	      defined suffixes other than .o as denoting object files.

       The processing of other files is implementation-defined.

       -l  library
	      (The letter ell.) Search the library named:

	      liblibrary.a

       A library is searched when its name is encountered, so the placement of
       a -l operand is significant. Several standard libraries can  be	speci‐
       fied  in this manner, as described in the EXTENDED DESCRIPTION section.
       Implementations may  recognize  implementation-defined  suffixes	 other
       than .a as denoting libraries.

STDIN
       Not used.

INPUT FILES
       The  input  file	 shall be one of the following: a text file containing
       FORTRAN source code; an object file in the format  produced  by	fort77
       -c;  or	a library of object files, in the format produced by archiving
       zero or more object files, using ar. Implementations may	 supply	 addi‐
       tional utilities that produce files in these formats.  Additional input
       files are implementation-defined.

       A <tab> encountered within the first six characters on a line of source
       code  shall  cause the compiler to interpret the following character as
       if it were the seventh character on the line (that is, in column 7).

ENVIRONMENT VARIABLES
       The following environment  variables  shall  affect  the	 execution  of
       fort77:

       LANG   Provide  a  default value for the internationalization variables
	      that are unset or null. (See  the	 Base  Definitions  volume  of
	      IEEE Std 1003.1-2001,  Section  8.2,  Internationalization Vari‐
	      ables for the precedence of internationalization variables  used
	      to determine the values of locale categories.)

       LC_ALL If  set  to a non-empty string value, override the values of all
	      the other internationalization variables.

       LC_CTYPE
	      Determine the locale for	the  interpretation  of	 sequences  of
	      bytes  of	 text  data as characters (for example, single-byte as
	      opposed to multi-byte characters in arguments and input files).

       LC_MESSAGES
	      Determine the locale that should be used to  affect  the	format
	      and contents of diagnostic messages written to standard error.

       NLSPATH
	      Determine the location of message catalogs for the processing of
	      LC_MESSAGES .

       TMPDIR Determine the pathname that should override the  default	direc‐
	      tory for temporary files, if any.

ASYNCHRONOUS EVENTS
       Default.

STDOUT
       Not used.

STDERR
       The  standard error shall be used only for diagnostic messages. If more
       than one file operand ending in .f (or possibly other unspecified  suf‐
       fixes) is given, for each such file:

	      "%s:\n", <file>

       may  be	written to allow identification of the diagnostic message with
       the appropriate input file.

       This utility may produce warning messages about certain conditions that
       do not warrant returning an error (non-zero) exit value.

OUTPUT FILES
       Object  files, listing files, and executable files shall be produced in
       unspecified formats.

EXTENDED DESCRIPTION
   Standard Libraries
       The fort77 utility shall recognize the following	 -l  operand  for  the
       standard library:

       -l f   This   library   contains	  all	functions  referenced  in  the
	      ANSI X3.9-1978 standard. This operand shall not be  required  to
	      be present to cause a search of this library.

       In  the	absence of options that inhibit invocation of the link editor,
       such as -c, the fort77 utility shall cause the equivalent of a -l f op‐
       erand  to  be passed to the link editor as the last -l operand, causing
       it to be searched after	all  other  object  files  and	libraries  are
       loaded.

       It  is unspecified whether the library libf.a exists as a regular file.
       The implementation may accept as -l operands names of objects  that  do
       not exist as regular files.

   External Symbols
       The  FORTRAN compiler and link editor shall support the significance of
       external symbols up to a length of at least 31 bytes; case  folding  is
       permitted.  The	action	taken  upon encountering symbols exceeding the
       implementation-defined maximum symbol length is unspecified.

       The compiler and link editor shall support a minimum  of	 511  external
       symbols	per source or object file, and a minimum of 4095 external sym‐
       bols total. A diagnostic message is written to standard output  if  the
       implementation-defined  limit  is  exceeded; other actions are unspeci‐
       fied.

EXIT STATUS
       The following exit values shall be returned:

	0     Successful compilation or link edit.

       >0     An error occurred.

CONSEQUENCES OF ERRORS
       When fort77 encounters a compilation error, it shall write a diagnostic
       to  standard  error and continue to compile other source code operands.
       It shall return a non-zero  exit	 status,  but  it  is  implementation-
       defined	whether	 an  object  module  is	 created.  If the link edit is
       unsuccessful, a diagnostic message shall be written to standard	error,
       and fort77 shall exit with a non-zero status.

       The following sections are informative.

APPLICATION USAGE
       None.

EXAMPLES
       The  following  usage example compiles xyz.f and creates the executable
       file foo:

	      fort77 -o foo xyz.f

       The following example compiles xyz.f and creates the object file xyz.o:

	      fort77 -c xyz.f

       The following example compiles xyz.f and creates	 the  executable  file
       a.out:

	      fort77 xyz.f

       The  following  example	compiles xyz.f, links it with b.o, and creates
       the executable a.out:

	      fort77 xyz.f b.o

RATIONALE
       The name of this utility was chosen as fort77 to parallel the  renaming
       of  the	C compiler. The name f77 was not chosen to avoid problems with
       historical implementations. The ANSI X3.9-1978 standard was selected as
       a  normative  reference	because	 the ISO/IEC version of FORTRAN-77 has
       been superseded by the ISO/IEC 1539:1990 standard (Fortran-90).

       The file inclusion and symbol definition #define mechanisms used by the
       c99    utility	 were	 not	included    in	  this	  volume    of
       IEEE Std 1003.1-2001-even though they  are  commonly  implemented-since
       there  is no requirement that the FORTRAN compiler use the C preproces‐
       sor.

       The  -onetrip   option	was   not   included   in   this   volume   of
       IEEE Std 1003.1-2001, even though many historical compilers support it,
       because it is derived from FORTRAN-66; it is an anachronism that should
       not be perpetuated.

       Some  implementations produce compilation listings. This aspect of FOR‐
       TRAN has been left unspecified because there was controversy concerning
       the  various  methods  proposed	for implementing it: a -V option over‐
       lapped with historical vendor practice and a naming convention of  cre‐
       ating  files  with .l suffixes collided with historical lex file naming
       practice.

       There  is  no  -I  option  in  this   version   of   this   volume   of
       IEEE Std 1003.1-2001  to	 specify  a  directory	for file inclusion. An
       INCLUDE directive has been a part of the Fortran-90 discussions, but an
       interface supporting that standard is not in the current scope.

       It  is  noted that many FORTRAN compilers produce an object module even
       when compilation errors occur; during  a	 subsequent  compilation,  the
       compiler	 may  patch  the object module rather than recompiling all the
       code. Consequently, it is left to the implementor  whether  or  not  an
       object file is created.

       A  reference  to	 MIL-STD-1753  was  removed  from an early proposal in
       response to a request from the POSIX FORTRAN-binding standard  develop‐
       ers.  It	 was  not  the intention of the standard developers to require
       certification of the FORTRAN compiler,  and  IEEE Std 1003.9-1992  does
       not specify the military standard or any special preprocessing require‐
       ments. Furthermore, use of that document would have been	 inappropriate
       for an international standard.

       The  specification  of optimization has been subject to changes through
       early proposals. At one time, -O and -N were Booleans: optimize and  do
       not  optimize  (with an unspecified default).  Some historical practice
       led this to be changed to:

       -O 0   No optimization.

       -O 1   Some level of optimization.

       -O  n  Other, unspecified levels of optimization.

       It is not always clear whether "good code generation" is the same thing
       as  optimization.  Simple optimizations of local actions do not usually
       affect the semantics of a program. The -O 0 option has been included to
       accommodate  the very particular nature of scientific calculations in a
       highly optimized environment; compilers make  errors.  Some  degree  of
       optimization  is	 expected,  even if it is not documented here, and the
       ability to shut it off completely could be important  when  porting  an
       application.  An implementation may treat -O 0 as "do less than normal"
       if it wishes, but this is only meaningful if any of the	operations  it
       performs can affect the semantics of a program.	It is highly dependent
       on the implementation whether doing less than normal is logical. It  is
       not  the	 intent of the -O 0 option to ask for inefficient code genera‐
       tion, but rather to assure that any semantically	 visible  optimization
       is suppressed.

       The  specification  of standard library access is consistent with the C
       compiler	 specification.	 Implementations  are  not  required  to  have
       /usr/lib/libf.a, as many historical implementations do, but if not they
       are required to recognize f as a token.

       External symbol size limits are in normative text; conforming  applica‐
       tions  need  to	know these limits. However, the minimum maximum symbol
       length should be taken as a constraint on a conforming application, not
       on  an  implementation,	and consequently the action taken for a symbol
       exceeding the limit is unspecified. The minimum size for	 the  external
       symbol table was added for similar reasons.

       The  CONSEQUENCES  OF  ERRORS section clearly specifies the behavior of
       the compiler when compilation or link-edit errors occur.	 The  behavior
       of  several historical implementations was examined, and the choice was
       made to be silent on the status of the executable, or  a.out,  file  in
       the  face  of  compiler	or  linker errors. If a linker writes the exe‐
       cutable file, then links it on disk with	 lseek()s  and	write()s,  the
       partially  linked  executable  file can be left on disk and its execute
       bits turned off if the link edit fails. However, if  the	 linker	 links
       the  image in memory before writing the file to disk, it need not touch
       the executable file (if it already exists) because the link edit fails.
       Since both approaches are historical practice, a conforming application
       shall rely on the exit status of fort77, rather than on	the  existence
       or mode of the executable file.

       The -g and -s options are not specified as mutually-exclusive.  Histor‐
       ically these two options have been mutually-exclusive, but because both
       are so loosely specified, it seemed appropriate to leave their interac‐
       tion unspecified.

       The requirement that conforming applications specify  compiler  options
       separately is to reserve the multi-character option name space for ven‐
       dor-specific compiler options, which are known to exist in many histor‐
       ical  implementations.  Implementations	are not required to recognize,
       for example, -gc as if it were -g -c; nor are they forbidden from doing
       so.  The SYNOPSIS shows all of the options separately to highlight this
       requirement on applications.

       Echoing filenames to standard error is considered a diagnostic  message
       because	it  would otherwise be difficult to associate an error message
       with the erring file. They are described with "may" to allow  implemen‐
       tations	to  use other methods of identifying files and to parallel the
       description in c99.

FUTURE DIRECTIONS
       A compilation system based  on  the  ISO/IEC 1539:1990  standard	 (For‐
       tran-90)	 may be considered for a future version; it may have a differ‐
       ent utility name from fort77.

SEE ALSO
       ar  ,  asa  ,  c99  ,  umask()  ,  the  System  Interfaces  volume   of
       IEEE Std 1003.1-2001, exec

COPYRIGHT
       Portions	 of  this text are reprinted and reproduced in electronic form
       from IEEE Std 1003.1, 2003 Edition, Standard for Information Technology
       --  Portable  Operating	System	Interface (POSIX), The Open Group Base
       Specifications Issue 6, Copyright (C) 2001-2003	by  the	 Institute  of
       Electrical  and	Electronics  Engineers, Inc and The Open Group. In the
       event of any discrepancy between this version and the original IEEE and
       The  Open Group Standard, the original IEEE and The Open Group Standard
       is the referee document. The original Standard can be  obtained	online
       at http://www.opengroup.org/unix/online.html .

IEEE/The Open Group		     2003			     FORT77(P)
[top]

List of man pages available for YellowDog

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net